Seller: stepperonline✉️(12,502)99.8%,
Location:Rowland Heights, California, US,
Ships to: US & many other countries,
Item:3344325379347.5KW VFD 10HP 31A 220V 3 Phase Variable Frequency Drive Inverter CNC.
Store Categories
Store Categories
Open Loop Stepper Motor
Nema 8 (20mm)
Nema 11 (28mm)
Nema 14 (35mm)
Nema 16(39mm)
Nema 17 (42mm)
Nema 23 (57mm)
Nema 24 (60mm)
Nema 34 (86mm)
Open Loop Driver
Nema 17 Driver
Nema 23 Driver
Nema 24 Driver
Nema 34 Driver
Open Loop Stepper Kit
Nema 23 Stepper Kit
Nema 34 Stepper Kit
VORON V0.1
Closed Lopp Stepper Kit
Nema 17--0.72Nm
Nema 23--1.2Nm
Nema 23 -- 2Nm
Nema 24 -- 3Nm
Nema 24--4Nm
Nema 34 -- 4.5Nm
Nema 34--4.8Nm
Nema 34--9Nm
Nema 34--12Nm
Nema 23--3Nm
Closed Loop Driver
Closed Loop Stepper
Servo Motor
VFD Variable Frequency Drive
MEAN WELL Power Supply
Enclosed Type
DIN Rail Power Supply
LED Power Supply
Power Supplies
Worm Gearbox
Planetary Gearbox
Geared Stepper Motor
Nema 17 Geared
Nema 23 Geared
Precision Planetary Geared
Linear Stepper
Motor Mounting Brackets
Stepper Motor Cable
Output Shaft for NMRV030
New Arrival
Top Selling Products
Clearance Sale
Output Shaft for NMRV040
Other
This VFD with power 10HP(7.5KW) and three phase 220V input voltage. The H100 series is General Variable Frequency Drive(VFD), they are widely used in application of: Textile machines, Packaging machines, Engraving machines, Printing machines, Food machinery, Woodworking machinery, Pump fans, Ceramic machinery, Solar pumps and others.
Package Content
1 x 7.5KW Variable Frequency Drive Inverter 1 x English Manual
Key Specification Rated Input Voltage: 3-Phase 220V Allowed Input Voltage: 180~260VAC Input Frequency: 50/60Hz(+/-5%) Input Current: 37A Power: 10HP(7.5KW) Output Current: 31A Output Voltage: 0~Rated Input Voltage Output Frequency: 0~1000Hz Output Capacity: 150% Rated Current 60s, 180% Rated Current 2s
Peripheral device connection Main circuit and function card Power terminal wiring instructions
For 220V class inverter, use class 3 grounding method(grounding resistance: less than 100Ω). Use special grounding terminal for grounding. Do not use screws for grounding in the box. Note: Grounding steps (1) Determine the location of the ground terminal. (2) Connect the ground-wire to the ground terminal and make sure that the screws are tight
Main circuit terminal description
Please implement the wiring in accordance with the regulations of electrician regulations to ensure safety When selection of the wire diameter specification
● It is best to use isolated wires or conduits for power wiring, and ground the isolation layer or conduits at both ends. ● Be sure to install the air disconnect switch NFB between the power supply and the input terminals(R / L1, S / L2, T / L2) ● Do not connect the AC power supply to the output terminal (U V W) of the inverter. ● The output wiring must not touch the metal shell of the inverter, in case of a short circuit to ground. ● Do not use phase shift capacitors, LC / RC noise filters and other components at the output of the inverter. ● The main circuit wiring of the inverter must be far away from other control equipment. ● When the wiring between the inverter and the motor exceeds 15 meters (220V level),(380V level 30 meters), a high dV / dT will be generated inside the motor coil, which will produce interlayer insulation of the motor then damaged, please use a special motor for the inverter or install a reactor on the inverter side.
Keyboard Features
On Aug 17, 2023 at 18:08:06 PDT, seller added the following information:
On Nov 20, 2023 at 18:43:25 PST, seller added the following information:
Condition:New
Power Rating:7.5 KW
Input Phase:3 Phase
Modulation Mode:SVPWM
Output Power:10HP / 7.5KW
Output Current:31A
UPC:749346653159
MPN:EV50T20075BX0
Input Voltage:220 V
Control Modes:V/F, SVC
Output Capacity:150% Rated Current 60s, 180% Rated Current 2s