Features:
1. The basic accuracy for measurement and output is 0.05%, display 5 digits.
2. Measurement function: DC voltage, thermocouple.
3. Output function: DC voltage, thermocouple.
4. 8 thermocouple types.
5. Auto cool-end compensation when output thermocouple.
6. C or F display.
7. 9V battery (not included), battery life is about 25 hours
8. Operation temperature: 0-50C; Humidity<=80%RH
9. Storage temperature: -10C to 55C; Humidity<=90%RH
9. Size: about 200x100x40mm
10. Weight: 550g
11. Accessories: test leads, PDF manual
Specifications:
Output |
Range |
Output range |
Resolution |
Accuracy |
|
Voltage |
100mV |
-10.00 ~110.00mV |
0.01mV |
±0.05% Setting value +30uV |
The max. output current ±5mA |
1000mV |
-100.00~1100.0mV |
0.1mV |
±0.05% Setting value ±0.3mV | ||
Thermocouple |
R |
-40~1760 ℃ |
1 ℃ |
±0.05% Setting value ±3 ℃ (≤100 ℃ ) |
Adopt the ITS-90 temperature |
S |
-20~1760 ℃ |
1 ℃ |
±0.05% Setting value ±2 ℃ ( > 100 ℃ ) |
standard (Note 1) | |
B |
400~1800 ℃ |
1 ℃ |
±0.05% Setting value ±3 ℃ (400~600 ℃ ) |
| |
±0.05% Setting value ±2 ℃ ( > 600 ℃ ) |
| ||||
E |
-200.0~1000.0 ℃ |
0.1 ℃ |
±0.05% Setting value |
| |
±2 ℃ (≤-100 ℃ ) |
| ||||
K |
-200.0~1370 ℃ |
0.1 ℃ |
|
| |
J |
-200.0~1200.0 ℃ |
0.1 ℃ |
±0.05% Setting value |
| |
T |
-200.0~400.0 ℃ |
0.1 ℃ |
|
| |
N |
-200.0~1300.0 ℃ |
0.1 ℃ |
±1 ℃ ( > -100 ℃ ) |
|
Measurement |
Range |
Output range |
Resolution |
Accuracy | |
Voltage |
100mV |
-10.00 ~110.00mV |
10uV |
±0.05% Measuring value ±30uV |
Input Resistance 1MΩ |
Thermocouple |
R |
-40~1760 ℃ |
1 ℃ |
±0.05% Measuring value ±3 ℃ (≤100 ℃ ) |
xInput tesistance1MΩ x |
S |
-20~1760 ℃ |
1 ℃ |
±0.05% Measuring value ±2 ℃ ( > 100 ℃ ) |
Adopt the ITS-90 | |
B |
400~1800 ℃ |
1 ℃ |
±0.05% Measuring value ±3 ℃ (400~600 ℃ ) |
| |
±0.05% Setting value ±2 ℃ ( > 600 ℃ ) |
temperature standard | ||||
E |
-200.0~1000.0 ℃ |
0.1 ℃ |
±0.05% Measuring value |
(Note 3) | |
±2 ℃ (≤-100 ℃ ) |
| ||||
K |
-200.0~1370 ℃ |
0.1 ℃ |
|
| |
J |
-200.0~1200.0 ℃ |
0.1 ℃ |
±0.05% Measuring value |
| |
T |
-200.0~400.0 ℃ |
0.1 ℃ |
|
| |
N |
-200.0~1300.0 ℃ |
0.1 ℃ |
±1 ℃ ( > -100 ℃ ) |
|
Note:
1. Not including the accuracy of inner temperature compensatory transducer.
The range of inner temperature compensatory transducer:-10-50°C, compensatory error ≤0.5°C.
2. Temperature coefficient : ±0.005% , range/°C(0°C-18°C,28°C-50°