See Details on eBay

110V 60HZ CW-5200DG Industrial Water Chiller for Single 130/150W CO2 Laser Tube

$698.61 or Best Offer Sold, CAD $282.25 Shipping, 60-Day Returns

Seller: signagewholesale (2,008) 99.3%, Location: Beijing,海淀, Ships to: Worldwide, Item: 222145805371 Overview CW-5200DG Industrial Water Chiller 0.93HP, AC 1P 110V, 60Hzfor Single 130/150W CO2 Laser Tube Cooling, 1400W cooling capacity, 30W DC pump, 1 outlet and 1 inlet. The water temperature is able to be adjusted. Comprehensive guarantee for 2 years except the wearing parts. High Quality! Buy with confidece. Hot-sale Water chiler. perfect customer service!! ModelCW-5200DG-USPower SupplyAC 110V, 60HzCurrent4.5~6.5ACompressor Power0.68KW0.93HPRefrigerating Capacity5186Btu/h1.52KW1307Kcal / hRefrigerantR-22 / R-134a / R-410aRefrigerant Charge350gPrecision±0.3℃Tank Capacity6LReducerCapillaryProtectionOver current protection for compressor, flow alarm, over temperature alarmPump Power0.03KWMaximum Flow10L / minMaximum Pumping Lift10MInlet and OutletExternal Φ10mm brass connectorNet Weight26kgGross Weight29kgProduct Dimension22.8" x 11.4" x 18.5" (580 x 290 x 470mm)Package Dimension27.6" x 16.9" x 22.8" (700 x 430 x 580mm) Alarm functionE1E2E3E4E5Over high room temperatureOver high water temperatureOver low water temperatureRoom temperature sensor failureWater temperature sensor failure Remark:When alarm occurs, the error code and the temperature will be alternately displayed.In alarming state, the alarm sound could be suspended by pressing any button, but the alarm display remains until the alarm condition is eliminated. Thermostat parameters list:OrderCodeProject SettingRangeFactorySettingNotes1F0Temperature settingF9 – F825Constant temperature control effecting2F1Temperature difference values-15 - +5-2Intelligent control effecting3F2Cooling hysteresis0.1 – 3.00.8 4F3Way of control0 - 111: intelligent0: constant temperature5F4Alarm for over high water temperature1 - 2010 6F5Alarm for over low water temperature1 - 2015 7F6Alarm for over high room temperature40 - 5045 8F7Password00 - 998 9F8The allowed highest water temperatureF0 - 4030 10F9The allowed lowest water temperature1 – F020 Description Our CW-5200 is refrigeration type industrial Water Chiller of 1400W cooling capacity. It’s mainly used to have the heat generated during the laser device working that gone through the refrigerating cycle in compressor refrigeration system and eventually transferred to the air. The water temperature is able to be adjusted. There are 2 specifications as 1 water outlet / inlet and dual water outlet / inlet, applicable to cool single laser glass tube. Have design patent Certificate, CE and RoHS Certificate. This Water Chiller has been sold largely to Europe, South America, Asia and other markets. Economic cooling equipment, easy to install and operate, compact and easily movable. Our industrial water chillers are popular for its 2 temperature control modes as constant temperature and intelligent temperature control. Under intelligent mode, the water temperature is adjusted according to ambient temperature. With that 1 key solution, customers no longer need to worry about the water temperature adjustment of seasonal changes. Features • 1400W cooling capacity; optional environmental refrigerant; • Compact size, long working life and simple operation; • ±0.3°C precisely temperature control; • The intelligent temperature controller has 2 control modes, applicable to different applied occasions; with various setting and display functions; • Multiple alarm functions: compressor time-delay protection, compressor overcurrent protection, water flow alarm and over high / low temperature alarm; • Multiple power specifications; CE approval; RoHS approval; • Optional heater and water filter. Details: Temperature controller panel: Under normal circumstance, the new intelligent temperature controller does not need to adjust the controlling parameters. It will self-adjust controlling parameters according to room temperature, guaranteeing to meet cooling requirements for machines. Alarm Function’s Description: Flow alarm and output ports: In order to guarantee the equipment will not be damaged while cooling water circulation is out of control, CW-5200series chillers possesses an unique low flow alarm protection. The cooling water circulation loop alarm causes and the work of the state table Normal Flow IndicatorFlow Alarm IndicatorBuzzerOutput PortsHi, H2Output PortsH1, H3Circulating pump works properlyONOFFNOT RINGDISCONNECTIONBREAKOVERBlocked cooling water circulation loopOFFONRINGBREAKOVERDISCONNECTIONAlarm of water shortageOFFONRINGBREAKOVERDISCONNECTIONFaulted circulating pumpOFFONRINGBREAKOVERDISCONNECTIONPower interruption///BREAKOVERDISCONNECTION Note: The flow alarm is connected to the normally open relay and normally closed relay contacts, requiring operating current less than 5A, working voltage less than 300V. CW5200 Cooling Method: Compression refrigeration Cool for Single 130W / 150W CO2 Laser Tube Adopt intelligent controller, it will automatically adjust control parameters according to room temperature changes. CW5000 Cooling Method: Compression refrigeration Cool for Single 80W / 100W CO2 Laser Tube Adopt intelligent controller, it will automatically adjust control parameters according to room temperature changes. CW3000 Cooling Method: Fan Thermolysis Cool for Single 60W / 80W CO2 Laser Tube It’s mainly used on the equipment for heat exchange between the heat and the air environment. The water temperature is related to ambient temperature. One-stop automatic intelligent temperature control: in different environment, user does not need to change setting due to it will automatically switch to appropriate operating temperature. CW-5200AG, CW-5200BG, CW-5200DG: Applied to cool a single 130W / 150W CO2 laser tube. CW-5200AH, CW-5200BH, CW-5200DH: Applied to a cool a single 8KW CNC spindle, welding equipment or two 100W CO2 laser tubes. CW-5200AI, CW-5200BI, CW-5200DI: Applied to a cool single 50W-75W laser diode, a single15W-30W solid-state laser or a single 30W RF laser tube.ModelCW-5200AGCW-5200BGCW-5200DGCW-5200AHCW-5200BHCW-5200DHCW-5200AICW-5200-BIVoltageAC 1P 220VAC 1P 220VAC 1P 110VAC 1P 220VAC 1P 220VAC 1P 110VAC 1P 220VAC 1P 220VFrequency50Hz60HZ60HZ50Hz60HZ60HZ50Hz60HZCurrent2.4-3.1A2.6-3.3A4.5-6.5A2.4-3.1A2.6-3.3A4.5-6.5A2.4-3.1A2.6-3.3ACompressor Power0.52KW0.5KW0.68KW0.52KW0.5KW0.68KW0.52KW0.5KW0.71HP0.68HP0.93HP0.71HP0.68HP0.93HP0.71HP0.68HPRefrigeration Capacity5084Btu/h4982Btu/h5186Btu/h5084Btu/h4982Btu/h5186Btu/h5084Btu/h4982Btu/h1.49KW1.46KW1.52KW1.49KW1.46KW1.52KW1.49KW1.46KW1281Kcal/h1561Kcal/h1307Kcal/h1281Kcal/h1561Kcal/h1307Kcal/h1281Kcal/h1561Kcal/hRefrigerant Charge360g380g350g360g380g350g360g380gPump Power0.03KW0.05KW0.1KWMac. Lift10M12M25MMax. Flow10L/min13L/min16L/minInlet and OutletExternal Diameter: 10mm brass connectorDiameter 10mm speedy connector Fill the water tank with purified water. Connect the water inlet of the water tank to the water outlet of the laser machine and connect the water outlet of the water tank to the water inlet of the laser machine. Connect the signal line of the water tank with that of the laser machine. Please see pictures below. Industrial cooling machine’s installation is very simple, the new machine for the first time using, you can install it as following steps. A.Open the package to check if the machine is intact and all the necessary accessories are completed. B.Open the injection port to feed cooling water. Observing the water level gauge and adding water slowly, be careful not to have the water overflowed! For the cooling of carbon steel equipment, the water should be added an appropriate amount of anti - corrosion agentia. Working in cold north area, it’s better to use noncorrosive antifreeze fluid. C.According to system conditions, please connect the water inlet and outlet pipe well. D.Plug in power, turn on the power switch. (Do not start up without water in the water tank!) (1) Power switch turned on, the circulation pump of the chiller starts working. The first time of operating may cause more bubbles in the pipe leading to a flow alarming occasionally, but running for a few minutes later, it will go back to normal. (2) After the first boot, you must immediately check whether the water pipe leaks. (3) Power switched on, if the water temperature is below the set figure, it is normal that fans and other components of the machine do not work. The temperature controller will automatically control the working conditions of the compressor, magnetic valve, fans and other parts based on the set controlling parameters. (4) As it takes a longer time to start the compressor and other components, according to different conditions, the time is range from seconds to minutes, so do not turn off the power and again on frequently. E.Check the water level in the water tank. The first startup of the new chiller empties the air in the water pipe, leading a slight water level decline, but in order to keep the water level in the green area, it’s allowed to add adequate water again. Please observe and record the current water level, and inspect it again after the chiller running for a period of time, if the water level drops obviously, please re-inspect the water pipeline leakage. F.Adjust parameters of temperature controller. CW-5000 series use an intelligent thermostat. Normally users do not need to adjust it. If it is really necessary, please refer to “Operating status and parameters adjustment.” One of the differences between the CW5200 water tank and the CW3000 tank lies in that the CW5200 water tank can keep the water at a uniform temperature. Its cooling function can keep the temperature at a certain value, which can be adjusted manually. All the parameters related to the water tank have been set as the correct value by our company before delivery. The user may refer to the parameter instruction manual of the water tank for detailed description on the parameters. It is strongly suggested that the user should not change the parameters without authorization. Our company accepts no responsibility for any insolvable problems caused by the user’s unauthorized changing of parameters Maintenance Cooling machine used in long term, you should open the machine and clean the dust in order to ensure good heat dissipation. You can use non – corrosive antifreeze if you are in the northern cold regions. Cautions 1. Please ensure that the power supply and electrical outlet are in good contact and the earth wire must be firmly grounded! Although the average operating current of the chiller is small, but the instantaneous operating current could be up to 6 ~ 10amps sometimes (The instantaneous operating current of models of AC110V power supply are possible to be up to 10 ~ 15amps). 2. Please make sure there is a stable and normal voltage for the working chiller! As the refrigeration compressor is more sensitive to the power supply and voltage, so the operating voltage of our standard product is of 200 ~ 250V (110V model is of 100 ~130V). If you do need a wider operating voltage range, customization is available for us. 3. To protect the pump, it’s strictly forbidden to run the chiller without having water in the storage water tank! The new machine is packed after draining whole water in the tank, so please make sure the tank has water inside before machine starting, otherwise it’s easily to have the pump damaged. When the water level is below the green (NORMAL) range of the water level gauge, the cooling capacity of our chiller will go down slightly. Hence please ensure the water level is within the green (NORMAL) range. To drain through circulating pump is strictly prohibited! 4. Please be sure that the air inlet and air outlet are in good ventilation! There must be at least 30cm from obstructions to the air outlet which is in the back of the cooler, and should leave at least 8cm between obstructions and the side air inlet. 5. The filter screen must be regularly cleaned! It’s essential to unpick and wash the dust gauze, or the serious blockage will cause breakdown to the chiller. 6. Please pay attention to the effect of the condensate water! With greater ambient humidity, when the water temperature is lower than the ambient temperature, the condensate water will generate on the surface of water circular pipes and the cooled components. If above circumstance appears, it is recommended to set a higher water temperature or keep pipes and cooled parts warm. Application: CW5200 water chiller for cooling Co2 laser cutting machine CW5200-water-chiller-cool-for-SYNRAD-RF-metal-lasers CW5200-water-chiller-for-cooling-argon-arc-welding-clamp CW5200-water-chiller-cool-for-blender CW5200-water-chiller-cool-for-lab-vacuum-pump Quality report Package: Wooden Box: There is total one carton box. Machine Dimension 22.8" x 11.4" x 18.5" (580 x 290 x 470mm) Machine Weight 57.2ib (26kg) Package Carton box Packing Size 27.6" x 16.9" x 22.8" (700 x 430 x 580mm) Gross Weight 63.8ib (29kg) Packing list: CW-5200DG-US water chiller machine1 setPower cable1 pcConnection hose1 pcSealing washer2 pcs250V/2A spare fuse (Mounted on the power socket interface within the insurance reserve)1 pcUser manual1 pc Alarm signal output plug 1 pc cooling water additive1 / 0 bottle P.S.: cooling water additive is forbidden by express company, so we could not put it into the package. You can buy it from local. Caution: The appliance is not to be used by children or persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction, children supervised not to play with the appliance! Package: Note: The Water Chiller is ordering production, need 3 to 5 days of stock up time. Why buy from us?Buy from the expert! All of our product is direct from original manufacturer, who also supplies the brand name to domestic market but with much higher price. We are in the industry so we understand what is good for you and what is not. We offer this special purchase and pass this saving direct to our customer, We use what we are selling so we will have the best support than other sellers.Buy from an direct importer! As a direct importer, we buy direct from manufactures so we can guarantee you have the lowest price and top quality products! In addition, we have bulk price to save your cost even more.We work Harder. We get the lowest possible delivery fee for you. We dispatch goods as soon as possible for your urgent order. We have customer support to save your time.We understand what you need in your business. WE can give you professional advices, suggestions and ways to further reduce your productions cost in the long run. Please free to contact us if you need more information. Attention: "We are honest, serious and respectful because we work for business, which values honesty and professionalism from its buyers." Shipping apps.froo.com | Froo www.froo.com | Froo Cross Sell, Free Cross Sell, Cross promote, eBay Marketing, eBay listing Apps, eBay Apps, eBay Application Condition: New, Brand: S&A, Model: CW-5200DG, MPN: Does Not Apply, Country/Region of Manufacture: China

PicClick Insights PicClick Exclusive
  •  Popularity - 1,642 views, 2.1 views per day, 776 days on eBay. Super high amount of views. High amount sold, 7 Sold, 5 Available.
  •  Price -
  •  Seller - 2,008+ items sold. 0.7% negative feedback. Top-Rated Seller! Ships on time with tracking, 0 problems with past sales.
Similar Items