Moeller PKZM0-20 - Motor-protective circuit-breaker 9 kW, 16 - 20 A

$40.00 Buy It Now or Best Offer, $20.00 Shipping, eBay Money Back Guarantee
Seller: watchmaker0202 ✉️ (354) 100%, Location: Thornhill, Ontario, CA, Ships to: CA, US, Item: 225128702318 Moeller PKZM0-20 - Motor-protective circuit-breaker 9 kW, 16 - 20 A. Moeller. PKZM0-20 - Motor-protective circuit-breaker, 9 kW, 16 - 20 A, Screw terminals Product range PKZM0 motor protective circuit-breakers up to 32 A Basic function Motor protection Notes Also suitable for motors with efficiency class IE3. Connection technique Screw terminals Contact sequence Max. motor rating AC-3 220 V 230 V 240 V [P] 5.5 kW AC-3 380 V 400 V 415 V [P] 9 kW AC-3 440 V [P] 11 kW AC-3 500 V [P] 12.5 kW AC-3 660 V 690 V [P] 15 kW Rated uninterrupted current [Iu] 20 A Setting range Overload releases   [Ir  ] 16 - 20 A short-circuit release   [Irm  ] max. [Irm  ] 310 A Phase-failure sensitivity IEC/EN 60947-4-1, VDE 0660 Part 102 Explosion protection (according to ATEX 94/9/EC)  PTB 10, ATEX 3013, Ex II(2) GD
Observe manual MN03402003Z-DE/EN. Notes Overload trigger: tripping class 10 A
Can be snapped on to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height.

TECHNICAL DATA General Standards IEC/EN 60947, VDE 0660,UL, CSA Climatic proofing Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Storage - 40 - 80 °C Ambient temperature Open -25 - +55 °C Ambient temperature Enclosed - 25 - 40 °C Mounting position Direction of incoming supply as required Degree of protection Device IP20 Degree of protection Terminations IP00 Protection against direct contact when actuated from front (EN 50274) Finger and back-of-hand proof Mechanical shock resistance half-sinusoidal shock 10 ms to IEC 60068-2-27 25 g Altitude Max. 2000 m Terminal capacity main cable Screw terminals Solid 1 x (1 - 6)
2 x (1 - 6) mm2 Terminal capacity main cable Screw terminals Flexible with ferrule to DIN 46228 1 x (1 - 6)
2 x (1 - 6) mm2 Terminal capacity main cable Screw terminals Solid or stranded 18 - 10 AWG Terminal capacity main cable Screw terminals Stripping length 10 mm Specified tightening torque for terminal screws Main cable 1.7 Nm Specified tightening torque for terminal screws Control circuit cables 1 Nm Main conducting paths Rated impulse withstand voltage [Uimp] 6000 V AC Overvoltage category/pollution degree III/3 Rated operational voltage [Ue  ] 690 V AC Rated uninterrupted current = rated operational current [Iu  = Ie  ] 20 A Rated frequency [f] 40 - 60 Hz Current heat loss (3 pole at operating temperature) 5.82 W Impedance per pole 5 mΩ Lifespan, mechanical [Operations] 0.1 x 106 Lifespan, electrical (AC-3 at 400 V) Lifespan, electrical [Operations] 0.1 x 106 Max. operating frequency 40 Ops/h Short-circuit rating DC Short-circuit rating 40 kA Short-circuit rating DC Notes up to 250 V Motor switching capacity AC-3 (up to 690V) 20 A Motor switching capacity DC-5 (up to 250V) 20 (3 contacts in series) A Trip blocks Temperature compensation to IEC/EN 60947, VDE 0660 - 5…40 °C Temperature compensation Operating range - 25…55 °C Temperature compensation residual error for T > 40 °C ≦ 0.25 %/K Setting range of overload releases 0.6 - 1 x Iu short-circuit release Basic device, fixed: 15.5 x Iu Short-circuit release tolerance ± 20% Phase-failure sensitivity IEC/EN 60947-4-1, VDE 0660 Part 102 Rating data for approved types Switching capacity Maximum motor rating Three-phase 200 V
208 V 5 HP Switching capacity Maximum motor rating Three-phase 575 V
600 V 15 HP Switching capacity Maximum motor rating Single-phase 115 V
120 V 1.5 HP Switching capacity Maximum motor rating Single-phase 230 V
240 V 3 HP Short Circuit Current Rating, type E 240 V 18 kA Short Circuit Current Rating, type E 480 Y / 277 V 18 kA Short Circuit Current Rating, type E Accessories required BK25/3-PKZ0-E Short Circuit Current Rating, group protection 600 V High Fault SCCR (fuse) 10 kA Short Circuit Current Rating, group protection 600 V High Fault max. Fuse 150 A Short Circuit Current Rating, group protection 600 V High Fault SCCR (CB) 10 kA Short Circuit Current Rating, group protection 600 V High Fault max. CB 125 A Short Circuit Current Rating, group protection 600 V High Fault SCCR with CL (fuse) 18 A Short Circuit Current Rating, group protection 600 V High Fault max. Fuse (with CL) 600 A Short Circuit Current Rating, group protection 600 V High Fault SCCR with CL (CB) 18 kA Short Circuit Current Rating, group protection 600 V High Fault max. CB (with CL) 600 A
  • Condition: New
  • Maximum Amperage: 20 A
  • Brand: Moeller
  • Number of Gangs: 18 - 10 AWG
  • Plug Type: Screw terminals
  • Number of Positions: 2
  • Number of Phases: 3
  • Number of Outlets: 3

PicClick Insights - Moeller PKZM0-20 - Motor-protective circuit-breaker 9 kW, 16 - 20 A PicClick Exclusive

  •  Popularity - 0 watchers, 0.0 new watchers per day, 576 days for sale on eBay. 0 sold, 1 available.
  •  Best Price -
  •  Seller - 354+ items sold. 0% negative feedback. Great seller with very good positive feedback and over 50 ratings.

People Also Loved PicClick Exclusive