In order to conform to the EMC limit values, all 8BVI inverter modules in the drive system connected to the 8B0F line filter must be operated at the nominal switching frequency (5 kHz). The total length of all motor cables on each drive system (and for each 8B0F line filter) is not permitted to exceed 250 m. The cable length between the 8B0F line filter and the 8B0P power supply module is not permitted to exceed 5 m. The maximum permissible motor cable length per motor connection must also be taken into consideration (see 8BVI inverter modules).
Line filter, passive, 16 A, 3x 480 VAC, 50/60 Hz, IP20Cooling and mounting type | Wall mounting |
Certifications | |
CE | Yes |
UKCA | Yes |
UL | cULus E225616 Power conversion equipment |
EAC | Yes |
Permissible network configurations | TT, TN |
Mains input voltage | Max. 3x 480 VAC ±10% |
Frequency | 0 to 60 Hz |
Continuous current | 16 Aeff |
Peak current | 24 Aeff (<1 min), 1x/h |
Reduction of continuous current depending on ambient temperature | |
Starting at 50°C | 0.165 A/K |
Reduction of continuous current depending on installation elevation | |
Starting at 1000 m above sea level | 0.8 Aeff per 1000 m |
Power dissipation | 6.1 W |
Line filter per EN 61800-3, category C3 | Yes |
Variant | |
L1, L2, L3 and L1´, L2´, L3´ | Terminals |
PE | M5 threaded bolt |
Shield connection | |
On mains | No |
On device | No |
Terminal connection cross section | |
Flexible and fine-stranded wires | |
With wire end sleeves | Max. 4 mm² |
Approbation data | |
UL/C-UL-US | 12 AWG |
CSA | 12 AWG |
Discharge capacitance | 0.4 µF |
Leakage current | 33 mA |
Permissible mounting orientations | |
Hanging vertically | Yes |
Horizontal, face up | Yes |
Standing horizontally | No |
Installation elevation above sea level | |
Nominal | 0 to 1000 m |
Maximum | 4000 m |
Pollution degree per EN 61800-5-1 | In preparation |
Overvoltage category per IEC 60950 | II |
Degree of protection per EN 60529 | IP20 |
Temperature | |
Operation | |
Nominal | 5 to 40°C |
Maximum | 55°C |
Storage | -25 to 55°C |
Transport | -25 to 70°C |
Relative humidity | |
Operation | 5 to 85% |
Storage | 5 to 95% |
Transport | Max. 95% at 40°C |
Dimensions | |
Width | 45 mm |
Height | 250 mm |
Depth | 70 mm |
Weight | 0.8 kg |