P-4: signal holding function. If there is trigger signal, clocking is reset, the relay remains on; when the signal disappears, after clocking "OP" time, the relay is off; if another signal is triggered during clocking, clocking will be reset.
How to Set Clocking Range: After setting the parameter value at mode selection, press "STOP" button to set the clocking range; XXX. The last decimal point lights up, range: 1 second to 999 seconds. XX. X The second last decimal point lights up, range: 0.1 seconds to 99.9 seconds X. X. X. all 3 decimal points light up, range: 1 minute to 999 minutes. For example, if you want to set "OP" as 3.2 seconds, light up the second last decimal point, and set digit display as 03.2 Parameter Description: "OP" - on time, "CL" - off time, "LOP" - number of cycle times (1-999 times, "---" represents infinite loop). These parameters are independent of each other, but are shared by each mode. For example, in P1.1 mode, set the on-time "OP" is 5 seconds, if you switch to P1.2 mode, its "OP" will also be 5 seconds. In the main interface (display 000), press "SET" button will display "OP" ( "CL", "LOP") and the corresponding time XXX; If the mode (such as the mode P1.1, P1.2, P1.3) only has "OP" time, press the "SET" key to display only the "OP" and the corresponding time; Some models (such as the mode P3.1, P3.2) have parameters "OP", "CL", "LOP", press "SET" button will display "OP" and the corresponding time, "CL" and the corresponding time, "LOP" and the corresponding number of times;
After setting mode, in the main interface press "SET" key to see information about the parameters of the current mode, very convenient.
How to Set Parameters:
1. First, read the instructions to determine the required operating mode.
2. The module is powered up, the display at the current work mode (P1.1 default mode), then enter the main interface; press and hold "SET" button for 2 seconds to enter mode selection interface; then press "UP", "DOWN" button to select the mode (P1.1 ~ P-4).
3. Select the mode (such as P3.2), then press the "SET" button, the parameter to be set flashes ( "OP" on-time, "CL" off time, "LOP" cycles ( "---" represents infinite loop)), press(or press and hold) "UP", "DOWN" button to adjust the parameter value; then press the "STOP" key to set the decimal point position to select the clocking range (0.1 seconds to 999 minutes); press the "SET" button to set the next parameters of the current mode, method is same as above.
4. After the parameters are set, press and hold "SET" button for 2 seconds, then the current mode will flash once, and then return to the main interface, which means the parameters are successfully set.
The main interface: If the relay is not in work state, it display "000" with no decimal point), if it is in work state, it has decimal point.
Mode selection screen: Press and hold the "SET" button to enter; after setting, press and hold the "SET" button to exit back to the main interface.
Relays Enable Mode:
1. ON: Relay allows conduction in the "OP" on-time;
2. OFF: Relay prohibits conduction and is always closed;
In the main interface, press the "STOP" button to switch between ON and OFF, the current state will flash, and then return to the main interface. (This feature is an emergency stop function, press on button to disconnect relay)
Sleep Mode:
1. "C-P" Sleep mode: five minutes without any operation, the digital display automatically turns off, the program running as usual;
2. "O-d" Normal mode: digital display turns on always;
Press hand hold the "STOP" button for two seconds to switch "C-P" and "O-d" state, the current state flashes and then return to the main interface.
Note:
1. The module is an active output, the output voltage equal to the input voltage.
2.'DC + 'and' load + ' are internally shorted(connected), but' DC- 'and' load - ' cannot be shorted, otherwise the load cannot be controlled on and off, which is equivalent to load being powered on always.
Package Includes:
1 x Timer Switch Module
Payment Shipping Policy Return Policy About us Contact us Payment 1.All payments must be prepaid. 2.We only accept payment via Paypal.Please kindly check if you can do the payment via paypal before placing an order. Shipping Policy 1. We are not responsible for undeliverable address, we reserve the right to charge the shipping fee again for returned items due to wrong address. 2. We will ship out your package by China post as soon as possible, it usually takes around 7-14 business days (USA, CA, AU, UK), others country takes around 10-20 business days (Brzil, India, RU), exact delivery time depends on postal process. 3. If you do not receive your item by 30 business days, Please feel free to contact us via ebay mail system, we will try our best to resolve any problems with you. 4. 4. the import tax/duty is the buyer's responsibility, not included in the price and the shipping fee. It is charged by the custom of your country. (Pls note, business days means Sat. & Sun. excluded) Return Policy 1. We offer 30 days money back guarantee return policy . 2. Our warranty does not extended to any products that are physically damaged or that are not under normal operating conditions as a result of misuse or improper installation on the buyer/user's part. 3. For all returned products, buyers MUST contact us for the returning address. 4. In all cases, buyers pay shipping fees at their own cost to return products for exchange or refund. We will be responsible for the postage of replacements. Refund will be made upon receipt of the returned item. About us We have office and warehouse in Australia and US to ensure fast shipment and after-sale service. We have more than 50 employees devoting to customer satisfaction. And more brands will be show in our store in near future. Contact us Our customer-oriented service strives for positive feedbacks with all 5 star selling ratings . Please feel free to contact us via eBay message once you have any question before you giving us negative feedback or open case. We will reply in 24 business hours . Business time: GMT8 (9:00-18:00) from Monday to Friday